Browse all practice questions for the Edelmen's Sonography Principles and Instrumentation (SPI) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Edelmen's Sonography Principles Exam 2026 – Complete SPI Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • Rayleigh scattering occurs when scatterers are smaller than wavelength.
  • A boundary roughness tends to cause which phenomenon?
  • What unit is commonly used to express an intensity ratio in ultrasound?
  • Which of the following is not typically a transducer component?
  • Dynamic range is defined as the ratio of the smallest to largest amplitude that can be processed without distortion.
  • Propagation speed increases most when which combination of material properties occurs?
  • Attenuation is measured in decibels per unit length and uses what type of scale?
  • Which of these intensities is the smallest?
  • Assuming a constant frequency, what happens if the diameter of an unfocused circular transducer is increased?
  • If the intensity of a sound beam remains unchanged while the beam area is reduced in half, what has happened to the power?
  • With the presence of which phenomenon do we see more boundaries than there are reflecting surfaces?
  • How many data bits are needed to represent 46 gray shades?
  • Which of the following represents the best lateral resolution?
  • Which technique improves the signal-to-noise ratio in ultrasound imaging?
  • The maximum frame rate in real-time ultrasound is primarily determined by
  • Doppler shift is maximal when the flow is parallel to the ultrasound beam.
  • If an ultrasound beam strikes a boundary at normal incidence and both media have the same propagation speed, which process cannot occur?
  • Rectification and smoothing are components of which of the following?
  • Which adjustment is most appropriate when the ultrasound image displays only strong reflectors with little background detail?
  • The Fresnel is the:
  • Which statement best describes destructive interference?
  • In a B-mode display, which axis is used for the amplitude of the reflection?
  • The duty factor for CW ultrasound is
  • In Doppler ultrasound, which incident angle results in no frequency shift?
  • Which is not an acoustic variable?
  • The more pixels per inch:
  • What can pulsed Doppler measure that continuous wave cannot?
  • Doppler Shifts always occur if the sound source and receiver are in motion.
  • Arrange the following media from fastest to slowest propagation speed in a typical medium:
  • How many bits are needed to represent 32 gray shades?
  • Which artifact is described as a ghosting artifact?
  • Changing which of the following would not cause any change in a hard copy image output?
  • Which of the following is a typical unit for amplitude of an ultrasound signal?
  • Which of the following is proportional to the square of the amplitude?
  • Among B-mode, gray-scale imaging, continuous-wave Doppler, and pulsed Doppler, which has the greatest output intensity?
  • PACS primarily provides which function in medical imaging workflows?
  • What happens to the speed of sound in a medium when the bulk modulus of the medium decreases?
  • Which notation correctly matches mega?
  • Which action is not typically part of the sonographer's duties?
  • Circumferences may be measured in which unit?
  • Destructive interference occurs when waves are
  • Pre-processing occurs at which stage in ultrasound image formation?
  • Which is most likely to create Rayleigh Scattering?
  • What Doppler angle is most inaccurate?
  • What is the frequency range for medical diagnostic Doppler transducers?
  • If the lines per frame is increased while the imaging depth remains unchanged, what happens to the frame rate?
  • If two media share the same propagation speed but have different densities, how does impedance change?
  • Is a sound wave a pressure wave made of compressions and rarefactions?
  • Which term describes the time between the start of one pulse and the start of the next pulse?
  • Which boundary produces the strongest reflection?
  • The Nyquist limit in Doppler ultrasound is defined as which of the following?
  • The grainy image texture due to interference of scattered waves is called:
  • If lines per frame are changed while imaging depth remains constant, what else would change?
  • Which statement about ultrasound frequency and resolution is true?
  • Which statement accurately describes the effect of increasing frequency on penetration depth?
  • Which term describes a transducer containing multiple active elements?
  • Axial resolution is improved by which change?
  • What is the primary purpose of compression in ultrasound imaging?
  • Which statement about wave speed is true?
  • For depth calibration accuracy in a test phantom, which properties are most relevant?
  • If we increase the frequency, the near zone length is:
  • Snell's law describes the physics of which phenomenon?
  • The amplitude of a boundary reflection depends on what property of the two media?
  • What effect do microbubble contrast agents have on ultrasound images?
  • Cavitation is most likely to occur under which condition?
  • In a system with a digital scan converter but an analog input signal, which component is required to convert the signal to digital form?
  • Shadowing in ultrasound imaging may occur due to what?
  • Which statement describes the impact of increasing the number of bits per pixel?
  • The digital scan converter has a number of pixels assigned to each bit.
  • The propagation speed of ultrasound in the AIUM test object is:
  • If the frequency is decreased, the numerical value of the radial resolution will be:
  • Which statement describes the effect of increasing transducer diameter on lateral resolution?
  • How many bits are needed to represent 1024 gray shades?
  • How many bits are needed to represent 16 shades of grey?
  • The speed of sound in soft tissue is closest to which value?
  • Which component is the active element in the transducer?
  • Which definition correctly describes the period of a wave?
  • If the frequency is doubled in the same medium, how does the propagation speed change?
  • What is the approximate decibel change when a signal's intensity is reduced to one half?
  • The following statement is true or false: A mirror image artifact can appear alongside true anatomy.
  • What is the elimination of voltages that do not exceed a certain level?
  • Which statement accurately describes reverberation artifacts?
  • In ultrasound safety, what does ALARA stand for in practice?
  • Power of sound has units of:
  • Which conversion turns digital signals into analog signals for display in imaging systems?
  • If an acoustic variable ranges from 55 to 105, what is its amplitude?
  • The ultrasound parameter most closely associated with cavitation risk is
  • What is another name for longitudinal resolution?
  • Which resolution is determined by the spatial pulse length?
  • Which control is used to compensate for signal loss with depth to keep brightness uniform?
  • Which factor primarily determines the signal amplitude at the transducer in an ultrasound system?
  • Coded excitation primarily improves imaging by what mechanism?
  • Which action is not typically performed by the sonographer?
  • The propagation speed of an ultrasound wave is equal to the product of which two quantities?
  • Which change improves lateral resolution by narrowing the beam width?
  • How does increasing frequency affect attenuation and penetration in soft tissue?
  • Which medium provides the fastest ultrasound propagation speed?
  • What is the term for the time from the start of a pulse to its end?
  • If the angle between the ultrasound pulse and the boundary is 56 degrees, this incidence is called?
  • If the frequency is tripled, what happens to the wavelength?
  • Which parameter is determined primarily by the medium through which ultrasound propagates?
  • Which component is primarily responsible for shaping the transmitted ultrasound beam and coordinating receive timing in an array system?
  • The Fraunhofer region in ultrasound corresponds to which zone?
  • In ultrasound, which region is where the beam is narrowest?
  • Enhancement, multipath, and side lobes result in which of the following?
  • Sound waves are which of the following?
  • What happens to venous blood flow to the heart during expiration?
  • Which option best completes the statement: A transducer ________ one form of ________ into another.
  • Which statement is true regarding frequency and penetration?
  • Which factor has the greatest influence on the pulse repetition period?
  • In ultrasound beam zones, which zone describes the far-field region after the focal point where the beam diverges?
  • In a homogeneous medium, if the speed of sound is 1540 m/s and the frequency is 2 MHz, what is the wavelength?
  • If the manufacturer increases the number of scan lines per frame, which may have to be decreased?
  • Which frequency range is typical for Doppler measurements?
  • Which statement describes the duty factor in pulsed ultrasound?
  • Doppler shifts depend on which of the following?
  • Which tissue type has propagation speed closest to soft tissue?
  • If the ultrasound instrument's output is increased by 60 dB, the beam intensity increases by approximately how many times?
  • What determines the propagation speed of ultrasound in a homogeneous medium?
  • The Doppler shift is a measure of which of the following?
  • Which clinical modality has the lowest output intensity?
  • What is the actual time that an ultrasound machine is creating a pulse?
  • Which of the following is not a beam steering technique for a mechanical scan head?
  • The sonographer can influence the duty factor of the ultrasound machine.
  • In soft tissue, distance traveled is equal to which factor times the round-trip time?
  • A hydrophone is used to measure which aspect of an ultrasonic signal?
  • What is the effect of increasing the pulse repetition frequency (PRF) on Doppler measurements?
  • Which statement describes the effect of increasing pixels per inch?
  • The range equation relates distance from the reflector to which two quantities?
  • The Doppler shift is the _______ of two frequencies.
  • Regarding dynamic range, increasing it affects grayscale in which way?
  • What are the units of intensity?
  • Which cavitation form is associated with shock waves and extreme energy release (violent collapse)?
  • Which quantity does Doppler shift primarily indicate?
  • If the frequency of a sound wave is doubled while traveling in the same medium, how is the wavelength affected?
  • If the intensity is increased by 3 dB, it:
  • What is a typical Doppler frequency?
  • Which has the greatest amount of attenuation?
  • What is the most typical Doppler shift measured clinically?
  • The region from the transducer to the minimum beam cross-sectional area is known as which zone?
  • In a pulsed ultrasound transducer, which factor primarily determines the emitted frequency?
  • Which Doppler modality is highly sensitive to low-velocity flow but does not provide velocity information?
  • DICOM is a standard for what in medical imaging?
  • According to AIUM bioeffects, there have been no confirmed bioeffects below intensities of what SPTA?
  • What is displayed on the x-axis of an M-mode image?
  • Images on a videotape are stored using which method?
  • Which component is responsible for converting echo timing into a display image by creating pixels from the received data?
  • Which of the following is ultrasonic and least useful in diagnostic imaging?
  • Which factor improves lateral resolution?
  • Which of the following is not a beam steering technique for a mechanical scan head?
  • The consolidation of many images into a single frame best describes which imaging concept?
  • All of the following are true EXCEPT:
  • A single-element transducer is focused by whom?
  • What is the effect of decreasing pulse duration on axial resolution?
  • If the output of the machine is increased by 20 dB, the beam intensity increases by how much?
  • To what factor does a 60 dB increase in output correspond, in terms of times?
  • Which type of artifact is most closely associated with depth errors caused by incorrect sound speed assumptions?
  • Which parameter most directly determines the maximum PRF in ultrasound imaging?
  • For a 5 MHz wave, which medium yields the longest wavelength?
  • What defines spatial pulse length?
  • If a 5 MHz wave travels through tissues such as fat, air, muscle, and bone, which will have the shortest wavelength?
  • If a 5 MHz wave is traveling in the tissues listed below, which will have the longest wavelength?
  • Which of the following has the greatest influence on temporal resolution?
  • Axial resolution is determined by which parameter?
  • With normal incidence, what factors affect refraction of ultrasound?
  • Which parameter is determined by the source?
  • Which is not a part of the transducer?
  • What is the name of the receiver function that corrects for attenuation?
  • Which unit is used to express volume measurements in ultrasound contexts?
  • From a safety standpoint, which method is best?
  • Which statement describes an exception about in-vitro bioeffects?
  • Sound Intensity decreased by 75% is how decibels of attenuation?
  • What should you do first when entering a hospital room to perform an ultrasound exam?
  • What is the trade-off of using higher frequency transducers?
  • Which of the following is NOT used to describe a single ultrasound pulse?
  • The statement 'A sonographer's education ends when they become registered' is
  • Which pair of medium properties determines the propagation speed of ultrasound?
  • If the wave amplitude doubles, what happens to the acoustic power?
  • A hydrophone is used to measure which property?
  • Which factor increases patient exposure during an ultrasound exam?
  • Decibels express the ratio of output quantities on a logarithmic scale. Which option reflects this concept?
  • The dynamic range is the ratio of the smallest to the largest ________ that a system can process without distortion.
  • Which statement best describes pulse repetition frequency (PRF)?
  • If output power increases by a factor of 4, how many decibels is this?
  • Which parameter controls the depth of imaging on the display?
  • All of the following are true of normal cavitation EXCEPT which statement?
  • Which of the following best describes the mechanistic approach to the study of bioeffects?
  • Under typical practice, a patient may revoke consent to treatment
  • If wires in an AIUM test object do not appear in the same place as on the display, what is amiss?
  • If the bulk modulus increases while density remains constant, the speed of sound will be
  • In a water tank scan, which region of the sound beam has the highest intensity?
  • Pulse repetition frequency (PRF) is measured in which units?
  • In real-time ultrasound, the relationship between imaging depth and frame rate is best described as
  • What are the units of longitudinal resolution?
  • Attenuation coefficient is typically expressed as
  • The beam diameter at the focus is one-half the transducer diameter.
  • A transducer with more than one active element is called:
  • With good images on the display but not on the printer, one should:
  • Which statement best describes a difference between annular and linear phased array transducers?
  • Which statement about exposure to acoustic energy is true?
  • How does speed change when bulk modulus increases?
  • To measure the ultrasound beam intensity, use a
  • Lateral resolution is improved by which factors?
  • Which cavitation form is characterized by stable bubble oscillation without collapse?
  • Coded excitation originates from which component of the ultrasound system?
  • If the frame rate increases and lines per frame are unchanged, what option best describes the change that occurs?
  • Which option best describes a sound beam in ultrasound?
  • Filling in of an anechoic region due to finite slice thickness is known as which artifact?
  • Which condition improves lateral resolution?
  • Which ultrasound system component generates the electrical pulse used to excite the transducer?
  • The production of deformation from voltage is called?
  • While propagating, a sound wave is refracted. Finally, it returns to the transducer. The system processes the sound wave as if it has:
  • If the frame rate rises and the lines per frame remain the same, the imaging depth must do what?
  • Which parameter controls image frame rate in ultrasound systems?
  • Impedance is the product of ________and ________.
  • The more bits per pixel:
  • Which of the following statements about Doppler frequency shift is true?
  • In ultrasound, the Fraunhofer zone corresponds to which region?
  • Which component in an ultrasound unit contains the memory bank?
  • Which statement about biological effects of ultrasound in laboratory settings is correct?
  • Which transducer is best suited for imaging superficial structures?
  • At an air–tissue interface, most of the ultrasound energy is reflected.
  • If the patient does not speak English, which action is best to obtain informed consent?
  • Which ultrasound safety index gauges heating potential?
  • If the transducer diameter increases, the lateral resolution at its smallest dimension is:
  • At an air–tissue interface, what fraction of the incident ultrasound energy is reflected?
  • Put in increasing order of propagation speed
  • If the round-trip time doubles, the reflector distance changes by what factor?
  • Which is an advantage of coded excitation in ultrasound imaging?
  • What measures the output of a transducer?
  • If a system is not displaying clear images in the far field, which component is most likely at fault?
  • Which description best characterizes an ideal epidemiological bioeffects study?
  • How many centimeters are in 60 millimeters?
  • If the angle between the ultrasound pulse and the boundary is 90 degrees, this incidence is called?
  • What is the effect of using a higher frequency on attenuation and imaging depth?
  • Which of the following best describes the empirical approach to the study of bioeffects?
  • A transducer ________ one form of ________ into another.
  • The reject control is used to adjust the appearance of which objects?
  • In which biological tissue will sound travel the fastest?
  • The production of a voltage from deformation is called?
  • Which form of cavitation is most likely to produce microstreaming in the intracellular fluid and shear stresses?
  • Impedance is defined as the product of propagation speed and density. Which pair of properties is involved?
  • Which artifact is NOT a cause of filling in an anechoic structure such as a cyst?
  • If 300,000 cycles occur in one second, what is the frequency?
  • An ultrasound system is set to 0db and is transmitting at full intensity. What is the output power when the system is transmitting at 10% of full intensity?
  • What is not the responsibility of the sonographer?
  • A quality assurance program:
  • What is the fraction of time that a transducer is transmitting?
  • ______ is the distance covered by one cycle.
  • Axial resolution is affected by focusing.
  • Which of the following conditions yields the highest mechanical index?
  • Which of the following is not one of the primary attenuation components?
  • If a system is not displaying clear images in the far field, this may indicate a problem with which component?
  • Which instrument is used to measure ultrasound beam intensity?
  • The process of reducing the difference between the smallest and largest voltages is called ________.
  • How is range ambiguity artifact eliminated?
  • Which of the following will result in the greatest number of shades of gray in a digital image display?
  • In soft tissue, the attenuation coefficient in dB/cm is approximately equal to one-half of which quantity, expressed in MHz?
  • Which pair best describes the factors that determine the speed of sound in a medium?
  • Which term describes the redirection of an ultrasound beam in many directions at a rough boundary?
  • What determines the frequency of a sound beam from a pulsed transducer?
  • True or False: With normal incidence, the angle is 180 degrees.
  • At the focus, the beam diameter is ______ the transducer diameter.
  • Volume has which unit?
  • What are the three attenuation components in ultrasound?
  • Which term describes the display feature that preserves echoes over time, helping visualize motion?
  • Which statement about ultrasound frequency and resolution is true?
  • Multiple reflections that are equally spaced are called:
  • Can grayscale imaging be adjusted by the sonographer?
  • The rayl is the unit of which property?
  • What is the primary function of the scan converter in an ultrasound system?
  • Power mode Doppler is typically associated with which characteristics?
  • A Thermal Index value of 3 implies what potential tissue temperature change?
  • Partial volume artifact occurs when echoes from adjacent structures are blended within a single voxel.
  • Which of the following is determined by the source and the medium?
  • Identify one of the advantages of coded excitation.
  • Which statement about spatial pulse length is true?
  • Which factor most directly determines axial resolution?
  • Rayleigh scattering in ultrasound occurs when scatterers are much smaller than the wavelength.
  • In depth calibration testing with a phantom, depth accuracy is most influenced by which property pair?
  • Doppler shifts are always created when the source and receiver are in motion relative to each other.
  • Decimal uses bases of 10; binary uses base 2. Which option lists the base for binary?
  • Which resolution improves most with focusing?
  • The Curie Temperature has which effect on the piezoelectric material in ultrasound transducers?
  • What is the location of the minimum cross-sectional area of the beam?
  • Which change would increase the mechanical index?
  • Which unit is typically used to express Doppler frequency shifts?
  • The region immediately beyond the near field is the far zone.
  • The gray-scale variation in a pulsed-wave Doppler spectrum primarily represents what?
  • Refraction occurs only if there is which combination?
  • As the impedance difference between two media becomes very large, which phenomenon increases?
  • If the number of scan lines per frame is increased, what happens to frame rate?
  • If the frequency is doubled, what happens to the period?
  • What is the effect of spatial compounding on image quality?
  • Which term describes the distance covered by one cycle?
  • Which of the following is associated with cavitation?
  • In a QA study using a tissue-equivalent phantom, adjusting a brightness control changes reflector brightness from fully bright to barely visible. Which system parameter are you evaluating?
  • Rectification and smoothing are associated with which processing stage?
  • How many decibels are related to a 90% decrease in imaging power?
  • ______ is the time to complete one cycle.
  • In the analog-to-digital converter path, which component stores the image data?
  • What is the minimum value of the duty factor?
  • Which device measures the acoustic output of a transducer?
  • Attenuation in soft tissue is closest to:
  • Which statement about Doppler shifts is correct?
  • An ultrasound system is set to 0db and is transmitting at full intensity. What is the output power when the system is transmitting at 50% of full intensity?
  • What is the standard for communication between medical imaging computers?
  • If 3 MHz sound has a 2 dB attenuation in 1 cm of tissue, what is the attenuation of 6 MHz sound in 0.5 cm of the same tissue?
  • Which artifact appears most commonly with highly reflective objects?
  • Impedance is the product of which two tissue properties?
  • What is displayed on the y-axis of an M-mode image?
  • If the beam area is doubled while intensity remains unchanged, power will
  • Which material yields the greatest attenuation?
  • The accuracy of reflector depth position on an A-mode, B-mode, or M-mode display is called?
  • All of the following will improve temporal resolution EXCEPT:
  • Dynamic range in ultrasound describes which of the following?
  • What information does Doppler shift provide?
  • In the empirical approach, the relationship studied is typically between exposure and response.
  • The angle between the motion and the ultrasound beam enters into the Doppler shift calculation as which trigonometric function?
  • The effects of soft tissue on ultrasound are called which property?
  • If frequency increases, the near zone length is:
  • Which term describes the fraction of time the machine is emitting a pulse?
  • The most likely amount of reflection at a boundary between soft tissue is:
  • What is the primary effect of increasing transmit power on image quality?
  • In a real time scanner, which factor determines the maximum frame rate?
  • What artifact has a grainy appearance and is caused by the interference effects of scattered sound?
  • Coded excitation is used to improve which aspect of image quality?
  • Post-processing occurs at which point in the imaging workflow?
  • Refraction requires oblique incidence and which condition?
  • If the distance to a target is doubled, the time-of-flight for the pulse round-trip is:
  • Doppler spectral aliasing is most likely to occur when:
  • What happens to reflections as impedance mismatch between media increases?
  • The dB is defined as the ______ of two intensities.
  • The creation of an image by scanning from different angles is best described as what?
  • Dynamic range in ultrasound systems is controlled by which control?
  • In A-mode ultrasound displays, how is depth represented?
  • If a reflector moves twice as far from the transducer, how does that affect the time-of-flight of the sound pulse?
  • The distance over which the ultrasound beam remains relatively narrow and maintains good lateral resolution is called which term?
  • If the spatial pulse length is 10 mm, what is the axial resolution?
  • Which boundary will create the strongest reflection?
  • If the power of a sound wave is increased by a factor of 8, how many decibels is this?
  • The units of attenuation are ___ : this is a ___ scale
  • To represent 16 shades of grey with minimum bits, how many bits are needed?
  • Harmonics in ultrasound imaging are created primarily in which medium?
  • Time-of-flight in ultrasound refers to what?
Subscribe

Get the latest from Examzify

You can unsubscribe at any time. Read our privacy policy